Minimum Time For Ucd Queue On Hold Message; Hunt Groups (Hg) - Siemens HiPath 1100 Programming Manual

Analog mf telephones
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Step by step
dgg
dd . mm
dfe
Minimum time for UCD queue on hold mes-
sage
This setting specifies a minimum length of time until a
message is played for calls waiting in a UCD queue.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
p
Enter the UCD subscriber group number (790 to 799).
w
Enter the minimum amount of time (00 to 99 in cycles
of 5 seconds) where 00 = 0 seconds (default)... 01 = 5
seconds (default)... 06 = 30 seconds, etc.
w
p
Enter the next UCD subscriber group number.
or
w
r
Press this key.
Initial status for programming mode.
This feature only works when the Time in a UCD
queue option (Code 031) is activated.

Hunt groups (HG)

A Hunt group is a group of extensions for answering
calls directed to a specific number identifying the
group. When an extension does not answer an internal
or external call within a specified period of time (see
Timeout within a Hunt group), the call will ring consec-
utively at the extensions that are available within the
group. When there is no signal, the extension may dis-
connect from the Hunt group.
Extensions can be grouped in a maximum of 10 Hunt
groups (780 to 789). The default setting assigns no ex-
tensions to Hunt groups.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
p
Enter the Hunt group number (780 to 789).
w
p
Enter the extension numbers (e.g., 11/101) to be includ-
ed in the Hunt group.
Programming an extension
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1120Hipath 1150Hipath 1190

Table of Contents