Programming an extension
Step by step
dge
dd . mm
dgf
q
64
Time in a UCD queue
This setting specifies the maximum length of time a call
is allowed to remain in a UCD queue.
Once the time expires, the call is disconnected or for-
warded to a UCD overflow call extension. The default
setting for a call to remain in a queue is 1 minute.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
p
Enter the UCD subscriber group number (790 to 799).
w
Enter the time allowed for a call to remain in a queue (00
to 99 in cycles of 5 seconds) where 00 = 0 seconds...
06 = 30 seconds... 12 = 1 minute (default), 99 = 8 min-
utes, 15 seconds.
w
p
Enter the next UCD subscriber group number.
or
w
r
Press this key.
Initial status for programming mode.
Waiting message before signaling a UCD call
This feature allows you to connect a call waiting mes-
sage for incoming calls before they ring at a UCD exten-
sion.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
p
Enter the UCD subscriber group number (790 to 799).
w
r
Activate/Disable call waiting message:
or
q
= Activated
r
= Deactivated (default)
w
p
Enter the next UCD subscriber group number.
or
w
r
Press this key.
Initial status for programming mode.