Resetting The Hot Tank Overload (High Limit Safety) - WaterLogic WL350 Operating, Installation And Service Manual

Hide thumbs Also See for WL350:
Table of Contents

Advertisement

RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY
1.
Red Compressor/Heater Switch must be in the O=OFF position
2.
Unplug the Power Cord from rear of WL350 Water Treatment System.
3.
Tower Model: Remove the Lower Front Panel by removing the Phillips Head Screws
underneath the Lower Front Panel.
Counter Top Model: Remove the Side Panel by removing Phillips Head Screws from
Side Panel.
4.
Locate the Protective Metal Box on the rear of the hot
tank. As you look through the condenser coils on the
rear of the unit, you will see the hot tank located on the
right hand side.
5.
From the front of the Water Treatment System, reach
up behind the hot tank and take hold of the protective
metal box covering the thermostat and overload on the
hot tank.
There are nuts that secure the Protective Metal Box to
the Hot Tank, are loose enough to allow you to remove
the Protective Metal Box.
If the nuts on the metal box are too tight, loosen the
nuts securing the Hot Tank to the upper base of the
WL350 Water Treatment System unit and lower the
Hot Tank so you can remove the Protective Metal Box.
WL350 Operating, Installation, and Service Manual
Page 16 – Revision 8-30-2016