RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY
 
 
 
 
 
Red Heater and Compressor Switch must be in the off position  
 
1. 
O=OFF 
 
2. 
Unplug the Power Cord from rear of WL250 Water Treatment System. 
Remove the Lower Front Panel of WL250 Water Treatment System by removing the Phillips 
3. 
head screws underneath the lower front panel. 
 
 
 
 
 
 
Locate the protective metal box on the rear of the hot tank.  
4. 
As you look through the condenser coils on the rear of the 
unit, you will see the hot tank located on the right hand side. 
 
 
 
 
 
From the front of the WL250 Water Treatment System, reach 
up behind the hot tank and take hold of the protective metal 
box covering the thermostat and overload on the hot tank. 
 
There are nuts that secure the metal box to the hot tank.  
However, the nuts are loose enough to allow you to remove 
the metal box. 
 
5. 
If the nuts on the metal box are too tight, loosen the nuts 
securing the hot tank to the upper base of the unit and lower 
the hot tank so you can remove the metal box. 
 
For demonstrative purposes, photos below have lowered the 
hot tank from the unit.
 