SERVICE MODE
COPIER>OPTION
FIX-TMP1
Use it to set a down sequence start temperature for plain paper.
Memo
Setting
0: 183°C
1: 178°C (default)
2: 173°C
3: not used (178°C)
TRSW-P-B
Use it to enable/disable transfer current output correction control at the
trailing edge of paper.
Setting
0: ON
1: OFF (default)
SP-MODE
Use it to turn on/off separation current output correction control.
Setting
0: standard mode (default)
1: low-voltage mode
FTMP-DWN
Use it to select stacking enhancement mode.
Memo
Setting
0: OFF (default)
1: lower by 5°C
2: lower by 10°C
3: lower by 15°C
DRUM-CLN
Use it to select drum cleaning enhancement mode.
Memo
Setting
0: 1000 single-sided copies (500 sheets*) (default)
1: 500 single-sided copies (250 sheets*)
2: 250 single-sided copies (125 sheets*)
3: 1000 single-sided (500 sheets*) copies if absolute moisture content is
9 g or more; 250 single-sided (125 sheets*) copies if fewer
4: do not stop rotation
(*: Double-sided copying)
S-86
If the user places priority on image quality, select '0'; on speed, se-
lect '2'.
The fixing temperature will be lowered to improve stacking perfor-
mance in the finisher.
• During copying, the drum rotation is stopped for about 1 sec as
soon as a specific number of sheets has been exceeded, thereby re-
covering the cleaning performance of the cleaning blade.
• If a cleaning fault occurs, change the setting in this mode.
• A higehr setting provides stronger effects.
COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000