Hide thumbs Also See for iR8500:
Table of Contents

Advertisement

CHAPTER 6 TROUBLESHOOTING

4.1.19 E067

Mounting condition
1) Are the primary charging assembly, pre-transfer charging assem-
NO:
Connection
2) Are the following connectors on the HV-DC PCB connected nor-
NO:
Wiring
3) Is the wiring from the HV-DC PCB to each charging assembly and
NO:
HV-AC PCB, HV-DC PCB
4) Disconnect the connector (J722) from the HV-DC PCB, and make
NO:
YES: Replace the HV-DC PCB, and connector J722 to end the work.
6-106
bly, and transfer/separation charging assembly mounted securely?
Mount them securely.
mally and the screws fitted normally? (See F06-401-02.)
• J721
• J723
• J730
Connect the connectors securely.
the wiring/connection from the HV-AC PCB to each charging as-
sembly normal?
Correct the wiring/connection.
copies. Is E067 indicated?
Replace the HV-AC PCB, and connector J722 to end the work.
J730
J721
J722 J723
COPYRIGHT© 2001 CANON INC.
F06-401-02
2000 2000 2000 2000
CANON iR8500 REV.0 MAR. 2001