4.1.15 E032

Connector
1) Is the copy data controller/NE controller connected firmly? (con-
NO:
DC controller PCB, Copy data controller/NE controller
2) Try replacing the copy data controller/NE controller. Is the problem
NO:
YES: Correct the problem.

4.1.16 E043

Side deck driver PCB
1) Is there electrical continuity between the connectors on the side
NO:
Deck main motor (M101), DC controller PCB
2) Try replacing the deck main motor (M101) of the side deck. Is the
YES: End.
NO:
COPYRIGHT© 2001 CANON INC.
nector J525 and J526 on the DC controller PCB)
Connect it firmly.
corrected?
Replace the DC controller PCB.
deck driver PCB indicated inthe following table?
Signal
38VU
J106-1
0VU
J106-2
Replace the side deck driver PCB.
problem corrected?
Check the harness from the DC controller PCB to the motor; if
normal, replace the DC controller PCB.
2000 2000 2000 2000
CHAPTER 6 TROUBLESHOOTING
Connectors
J101-1
J101-2
CANON iR8500 REV.0 MAR. 2001
6-103