CHAPTER 5 MAINTENANCE AND INSPECTION
5.17 Paper Sensor
5.17.1 Removing the Claw Jam Sensor
1) Remove the fixing assembly from the
copier.
2) Remove the two screws, and detach the
lower separation claw assembly.
3) Remove the claw jam sensor [1] from
the right side of the lower delivery as-
sembly.
5.17.2 Removing the External Delivery Sensor
1) Remove the external delivery roller.
2) Remove the two screws [1], and discon-
nect the connector [2]; then, detach the
external delivery sensor assembly [3].
3) Disconnect the connector [4], and de-
tach the external delivery sensor [5].