Device Configuration - Sierra Wireless AirLink ES440 User Manual

Aleos 4.4.0 software configuration
Hide thumbs Also See for AirLink ES440:
Table of Contents

Advertisement

2: Device Configuration

Rev 1 Nov.14
To access ACEmanager:
1. Insert the SIM card, if applicable. Refer to the AirLink device user
guide for details.
2. Power on the AirLink device.
3. Launch your browser and enter the IP address and port number
http://192.168.13.31:9191
ACEmanager is supported on the latest versions of Internet
®
®
Explorer
and Firefox
4. Log in:
· User Name: "user" (entered by default) or "viewer
Use the "user" login for configuring or monitoring your device.
Logging in as "viewer" only allows you to view the configuration
and connection state. You cannot make any configuration
changes.
· Default Password: 12345
Note: ACEmanager has a default session idle timeout of 15 minutes. If there
is no activity for the idle timeout period, you are redirected to the login
screen. To change the session idle timeout period, see
Session Idle Timeout (minutes)
To prevent others from changing the AirLink device settings, you can
change the ACEmanager password
Figure 2-1: ACEmanager: Main Login screen
After your initial login to ACEmanager, you have the option of
displaying the device status parameters on subsequent login
screens.
5. In ACEmanager, go to Services > Device Status Screen.
6. In the Device Status on Login Screen field, select Enable. (For
details, see
Device Status Screen
.
ACEmanager
on page 156.
(Chapter
13).
on page 195.)
2
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents