Checking The Pulser Coil Peak Voltage; Checking The Cdi Unit Peak Voltage - Yamaha e60hmhd Service Manual

Hide thumbs Also See for e60hmhd:
Table of Contents

Advertisement

IGNITION SYSTEM
CHECKING THE PULSER COIL PEAK
VOLTAGE
Measure:
• Pulser coil output peak voltage
Below specification
pulser coil.
Pulser coil output peak voltage
W/R-B(#1), W/B-B(#2), W/G-B(#3)
r/
Cranking
min
Opened Closed
D.C.V.
2.4
Peak voltage adaptor:
YU-39991/90890-03172
Pulser coil resistance (reference data)
W/R-B(#1), W/B-B(#2), W/G-B(#3)
CHECKING THE CDI UNIT PEAK
VOLTAGE
Measure:
• CDI unit output peak voltage
Below specification
unit.
CDI unit output peak voltage
Cranking
r/min
Opened Closed
D.C.V.
Peak voltage adaptor:
YU-39991/90890-03172
NOTE:
Before measuring CDI unit output peak
voltage, make sure that no abnormality is
observed on the charge coil and the pulser
coil.
8-10
Replace the
1,500
3,500
2.2
6.1
10.5
117 - 143 Ω
Replace the CDI
B/W -B
1,500
3,500
102
141
107
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

E60ehE60hwdE60hwhdE60mh

Table of Contents