17.5 FUNCTION (Operation/Inspection Mode)

17.5.1 COPIER

17.5.1.1 COPIER Table

/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
1. INSTALL
Sub item
STIR-4
STRD-POS
CARD
KEY
AINR-OFF
E-RDS
RGW-PORT
COM-TEST
COM-LOG
RGW-ADR
CNT-DATE
CNT-INTV
INIT-Y
INIT-M
INIT-C
INIT-K
COPIER>FUNCTION>INSTALL
This mixes the developing solutions inside the developers of all the colors.
The Y, M, C and Bk developers are raced for two minutes to ensure that the developing solutions are mixed.
Automatic detection of CCD scanning position in DF stream reading
Used to make card reader installation settings.
Setting values
1 to 2001 [Factory default/After RAM clear: 1]
Operation method Enter the number of cards to use. (You can use up to 1,000 cards from the entered number.)
Initialize the card management information.
- Initialize the card name (department ID) (from the entered number).
- Initialize the card's password.
Used to set management key function recognition.
Setting values
0: Don't recognize management key function (value at time of factory shipment).
1: Recognize management key function.
Operation method
1) Select COPIER > INSTALL > KEY, then enter '1'
2) Turn the main power switch OFF/ON (the management key function is now recognized).
Walm-up-rotation disable setting at initial installation
This disables the initialization of the P-CRG which is performed when a new P-CRG has been inserted. It prevents the
fuse from blowing when the P-CRG initialization has been completed.
It is used when replacing the P-CRG and checking the images in situations when, for instance, the causes of trouble are
identified. When it is set to "1," the initialization is canceled and the fuse is not blown even when a new P-CRG has been
inserted.
Settings
0: Initialization is performed when a new unit is inserted. The fuse is blown.
1: Initialization is not performed when a new unit is inserted.
[Factory setting/value after clearing RAM: 0]
E-RDS settings
Setting values
0: Not in use
1: In use
[Factory settings and after RAM clear: 0]
Specify port number of sales company server used in E-RDS
Setting range: 1 to 65535
[Factory settings and after RAM clear: ]
Check connection with sales company server used in E-RDS
Checks sales company server connection. Judges whether connection can be made and displays the results as OK or
FAIL.
Display detailed results of communication test with sales company server used in E-RDS
Displays information on any errors that have occurred in connection with sales company server.
Specify URL of sales company server used in E-RDS
Sets sales company server URL.
Set timing of counter transmission to server
Sets time and date for start of transmission of counter information to server, via E-RDS third party extension function.
Setting range: YYYYMMDDHHMM (YYYY: year, MM: month, DD: date, HH: hours, MM: minutes)
[Factory settings and after RAM clear::000000000000]
Note
This item is only displayed when the E-RDS third party extension function is enabled.Set timing of counter transmission
to server
Sets time and date for start of transmission of counter information to server, via E-RDS third party extension function.
Setting range: YYYYMMDDHHMM (YYYY: year, MM: month, DD: date, HH: hours, MM: minutes)
[Factory settings and after RAM clear:: 000000000000]
Note
This item is only displayed when the E-RDS third party extension function is enabled.
Set interval of counter transmission to server
Sets transmission intervals for transmission of counter information to server, via E-RDS third party extension function.
Y color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
M color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
C color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
K color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
T-17-41
Description
Chapter 17
0013-9278
level.
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
17-39