Canon iR C3380 series Service Manual page 343

Hide thumbs Also See for iR C3380 series:
Table of Contents

Advertisement

[1]
4) Remove the 2 screws [1].
[1]
5) Turn the handle [1] 180 deg. Pull the process unit [3] out until it is stopped
while holding the handle [1] and the grip [2].
[2]
6) Detach the inside front right cover [1].
- 2 screws [2]
[3]
F-10-41
[1]
F-10-42
[3]
[1]
F-10-43
7) Detach the hopper unit cover [1].
- 3 screws [2]
[2]
8) Detach the inside front left cover [1].
- 3 screws [2]
[2]
[1]
[2]
9) Disconnect the 17 connectors [2] and remove the screw [3] from the
hopper unit relay PCB [1] to remove the grounding wire.
[2]
[1]
F-10-44
[2]
[1]
[2]
F-10-45
F-10-46
Chapter 10