Automatic Thick Media Adjustment

Introduction
Scanners with Automatic Thickness Adjustment Control (ATAC) have an ATAC key
on the operator's panel.
You use the key to raise and lower the pressure-platen. You can change the insertion slot
size (pressure-platen height) on your scanner from 2mm to 15 mm (up to 0.6").
Originals up to 2mm thick should be scanned with the pressure all the way down (normal
position). Thicker originals will require you use the ATAC key to adjust for thick media.
To adjust the insertion slot for thick media with ATAC:
Press the ATAC key on your operator's panel to set the scanner in ATAC mode.
1.
The Paper Ready Indicator blinks yellow indicating the scanner is in ATAC mode but
2.
not yet ready, i.e., the pressure-platen is not yet positioned for the thick original.
Press and hold the Paper Forward key (arrow up) key to raise the pressure-platen until
3.
there is room to insert the thick original.
Insert the thick original evenly for a straight scan path.
4.
Press and hold the Paper Reverse (arrow down) key to lower the pressure-platen until the
5.
pressure-platen stops on its own.
The Paper Ready indicator will stop blinking and remain yellow when the pressure-platen
6.
is positioned correctly and is ready for thick media scanning.