Camera Alignment and Calibration

Introduction
Scanner calibration is very easy to perform with the Scanner Maintenance program you
installed with your drivers.
After manually cleaning the scan area, you just insert a calibration sheet, start the Scanner
Maintenance program and let the wizard take over.
Note:
Cleaning and calibration are tied together. Cleaning the scanner creates the need for
renewed calibration and correct calibration will always require a clean scan area.
Note:
The best quality of a calibration is generated after 1 hour warming-up of the scanner
lamp.
#
Action
1
Turn the scanner power ON
Make sure that the scanner has
been turned ON for at least 5
minutes prior to camera align-
ment and calibration. The short
warm-up time will ensure that
light conditions and camera
heights have stabilized
2
Launch the scanner mainte-
nance program
1. On your PC - Right click on
the scanner icon
2. Select Launch Scanner Main-
tenance to open the program's
welcome dialog.