11.1.7

SERVICE LIST (In SERVICE MODE only) [MENU], [9], [6]

Service list can be printed by service technicians as part of maintenance operations to confirm machine
settings or communication management records (protocol, total errors, function, and so on.) The con-
tents can be printed by selecting a menu item. Any of the items listed below can be selected by scrolling
the highlighted item using the [ ] or [ ] key, or by performing the keystrokes indicated for each list.
SERVICE LIST
01 . PROTOCOL TRACE
02 . TOTAL ERRORS
03 . FUNCTION
04 . DRUM HISTORY
05 . MEMORY DUMP
[ 1 ] PROTOCOL TRACE [MENU], [9], [6], [01]
This list is output to confirm communication protocol. In the output list, the result of the most recent
(last) facsimile communication is recorded. The following items are to be recorded.
Signal send/Receive time (TIME)
The time to start sending or receiving the signal is indicated as "MM: SS".
Signal send/Receive (S/R)
Signals sent by this machine are indicated as "S" and signals received by this machine
are indicated as "R". The high-speed training signal is indicated as "TCF" and high-speed image signal
is indicated as "PIX".
Facsimile Control Field (FCF DATA)
The first and second FCF commands are printed.
Facsimile Information Field (FIF DATA)
If there is an information field, its contents are printed in either HEX, BIN or TEL format. In "TEL" format,
LSB and MSB in "HEX" format are reversed.
Convert FIF to ASCII (ASCII)
FIF is converted to ASCII code before being printed.
1) Use the [ ] or [ ] key to select the "01.PROTOCOL TRACE", and then press the [ENTER] key.
2) Use the [ ] or [ ] key to select the line, and then press the [ENTER] key.
3) After completing the list output, the display returns to the standby mode screen. For a sample list,
refer to
P.12-1 "12.1.1 Protocol Trace List".
Note:
The firmware version (installed in this machine) is listed in the upper right corner of the Protocol
Trace List.
January 2005 © TOSHIBA TEC