Toshiba e-STUDIO170F Service Manual page 185

Hide thumbs Also See for e-STUDIO170F:
Table of Contents

Advertisement

PC FUNC 3
Bit
7
Retry Counter value at PC transfer:
6
0000 to 1111... counts up for each retry.
5
0000: No retry
4
0001: 1 retry
0010: 2 retries
.
.
0101: 5 retries
.
.
1111: 15 retries
3
Retry interval for PC transfer:
2
0001 to 1111... counts up for each minute.
1
0000: default (2 minutes)
0
0001: 1 minute
0010: 2 minutes
.
.
1111: 15 minutes
Remark:
PC FUNC 3 Bit 7 to 4:
This switch specifies the number of retries for data transmission to the PC.
PC FUNC 3 Bit 3 to 0:
This switch specifies the time intervals between retries in data transmission to the PC.
Default table
BIT US
CA
SG
HK
7
0
0
0
0
6
1
1
1
1
5
0
0
0
0
4
1
1
1
1
3
0
0
0
0
2
0
0
0
0
1
1
1
1
1
0
0
0
0
0
January 2005 © TOSHIBA TEC
Contents
DE
GB
IT
BE
NL
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
4 - 125
FI
ES
AT
CH
SE
DK NO
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
Link with User
Function Setting
-
-
PT
FR
AU
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
e-STUDIO170F Function Settings