(5)
Remove the ground cable from the W1 or W2 on the NCU PBA.
(6)
Release the three hooks of the PBA plate, and remove the NCU PBA.
Notes:
Carefully handle the boards that are directly connected together to avoid damaging the con-
nectors and boards.
For IT, DK, and FI machines of EU model, connect the ground cable to the W1. Connect the
ground cable to the W2 with the machines of EU and AU models for all other destinations.
US/CA, SG and HK model equip the terminal W1 only (no W2 is equipped).
January 2005 © TOSHIBA TEC
PBA plate
Hook
NCU PBA
Fig.8-12
8 - 11
Hook
W1 or W2