[ 5 ] Status codes
Using the 3-digit status code printed in the mode column of the communication journal, the communica-
tion mode of each job can be confirmed.
Each of the 3 digits of the status code has an individual meaning. These digits represent the following.
1st digit
Mode
TX Speed (bps)
0
1
2
3
4
5
6
2nd digit
Mode
Line density
0
8 x 3.85
1
2
8 x 15.4
3
4
16 x 15.4
8
300 dpi
3rd digit
Mode
Encoding
0
1
2
3
e-STUDIO170F Troubleshooting
2400
4800
7200
9600
12000
14400
V.34
8 x 7.7
-
MH
MR
MMR
JBIG