[ 5 ] SENSOR TEST [MENU], [9], [4], [05]
This test checks the actions of various sensors. The results are displayed on the LCD in the form of
binary data. The displayed data will be changed by changing the state or status of the applicable sen-
sor.
1) Use the [ ] or [ ] key to select "05. SENSOR TEST", and then press the [ENTER] key.
Remark:
The binary data on the LCD display means and its set contents the following.
Top cover open detect
(0: Open/1: Closed)
Not used
Document sensor detect
(0: Absence/1: Presence)
Document position sensor detect
(0: Absence/1: Presence)
2) When you complete the check, press the [STOP] key to return to the standby mode screen.
3) Depending on the result of the test, replace the applicable sensor, Operation panel assembly, etc.
referring to
P.8-1 "8. Removal/Replacement/Adjustment".
January 2005 © TOSHIBA TEC
SENSOR CHECK
X XXX XX X
11 - 19
Optional tray sensor detect
(0: Absence/1: Presence)
Optional paper end sensor detect
(0: Absence/1: Presence)
Paper end sensor detect
(0: Absence/1: Presence)