[ 2 ] Main PBA
Before disassembling or reassembling, be sure to refer to
sembling".
(1)
Remove the NCU PBA. (
(2)
Disconnect the eighteen connectors from the main PBA.
(3)
Remove the seven screws from the main PBA, and remove the main PBA and ground cable.
Caution:
There is a danger of a component explosion, if the battery is incorrectly replaced. Replace only
with the same or equivalent type recommended by the manufacturer. Dispose of used batteries
according to this manual.
Note:
After reassembling, turn the power switch ON, and execute and confirm the following:
-
Perform the memory clear (ALL) referring to the
[MENU], [9], [5], [01]"
-
Set the country/region where the machine is used referring to the
try/Region Setting"
-
According to the pre-output lists of the registration and programming, set the function
again.
-
Perform the edge registration adjustment referring to the
tion"
-
Reset all counter data in the memory write mode using the hex data provided on the com-
munication journal referring to the
[03]"
SCAN COUNT: F06DAA - F06DAD
PRINT COUNT: F06DB2 - F06DB5
DRUM COUNT: F06E0A - F06E0D
e-STUDIO170F Removal/Replacement/Adjustment
P.8-10 "[ 1 ] NCU PBA")
Fig.8-13
P.11-28 "[ 3 ] MEMORY WRITE [MENU], [9], [5],
8 - 12
P.8-1 "8.1 Before Disassembling or Reas-
Ground cable
Screw
Screw
P.11-25 "[ 1 ] MEMORY CLEAR
P.8-58 "8.3.2 Coun-
P.8-56 "8.3.1 Edge Registra-
January 2005 © TOSHIBA TEC
Screw