How to set up
Press Menu to activate the menus and select Input → Input locking.
Press ENTER.
The Input locking window is displayed with the current selection.
Use the ▲ or ▼ key to select a input to lock on.
Image 8-14
Main window
Image 8-16
Input locking
Input on Main window Output is locked on the selected source of the main window
Input on PIP window Output is locked on the selected source of the Pip window
Input 1
Input 2
Input 3
Input 4
Free run
When Input locking is set to a specific input and there is no sync signal available, the locking will be switched
to Free run without changing the user settings. Once the sync is available, it applies again the user settings.
Options for Free Run
When free run is selected, radio button selected, then the Free Run Options become available.
R5905158 HDF SERIES 16/06/2015
Output is locked on input 1
Output is locked on input 2
Output is locked on input 3
Output is locked on input 4
Output is locked on an internal sync (60 Hz or manual setup)
Image 8-15
Input
8. Input
77