Error Messages In Gp-Gl Command Mode - GRAPHTEC CE3000-40 User Manual

Table of Contents

Advertisement

Error messages in GP-GL command mode

Error message
GP-GL ERROR 1
An unrecognizable command was received.
Noise was received when the computer was turned
on.
The software command settings for controlling the
cutting plotter have been changed.
The data-transmission settings have been changed in
the interface settings.
GP-GL ERROR 2
The command terminator is incorrect.
The software settings for the output device have been
changed.
The data-transmission settings have been changed in
the interface settings.
GP-GL ERROR 3
The command delimiter is incorrect.
The software settings for the output device have been
changed.
The data-transmission settings have been changed in
the interface settings.
GP-GL ERROR 4
The command parameter exceeds the permissible
range.
The software settings for the output device have been
changed.
The data-transmission settings have been changed in
the interface settings.
GP-GL ERROR 5
An error occurred in the reception of data within the
interface.
The software command settings for controlling the
cutting plotter have been changed.
The data-transmission settings have been changed in
the interface settings.
Cause
6 – 5
Solution
Press the ENTER key to cancel the
error.
Set the software command settings
for controlling the cutting plotter.
Set the correct data-transmission
conditions.
Set the software command settings
for controlling the cutting plotter.
Set the correct data-transmission
conditions.
Set the software command settings
for controlling the cutting plotter.
Set the correct data-transmission
conditions.
Set the software command settings
for controlling the cutting plotter.
Set the correct data-transmission
conditions.
Set the software command settings
for controlling the cutting plotter.
Set the correct data-transmission
conditions.

Advertisement