Chapter 3 Configuration Settings and Display
3.1 Thin Provisioning Pool Management > expand thin-pro-pool

expand thin-pro-pool

This command expands the capacity of an existing Thin provisioning pool with the specified disks and
assigned cm. A Thin provisioning pool can be expanded by adding a new RAID group.
Syntax
expand thin-pro-pool {-pool-number
-rg-mode {auto|manual} [-disks
[-assigned-cm {0 | 1 | cm0cpu0 | cm0cpu1 | cm1cpu0 | cm1cpu1 | cm2cpu0 | cm2cpu1 | cm3cpu0 |
cm3cpu1 | cm4cpu0 | cm4cpu1 | cm5cpu0 | cm5cpu1 | cm6cpu0 | cm6cpu1 | cm7cpu0 | cm7cpu1 | auto}]
Parameter
-pool-number
or
-pool-name
-rg-mode
-disks
-capacity
-assigned-cm
pool_number
disks
] [-capacity
This parameter specifies the Thin provisioning pool identifiers.
Only one Thin provisioning pool identifier can be specified. For details, refer to
Provisioning Pool Syntax" (page
This parameter specifies the method of selecting the disk when creating the new RAID group.
auto
The disk is automatically allocated. The capacity of the disk is specified with the -
capacity parameter.
manual
The disk is manually allocated. The disk is specified with the -disks parameter.
Optional. This parameter specifies which disks are used to configure the RAID group. This
parameter can only be specified when "-rg-mode manual" is selected. One or more disks can
be specified at the same time. For details, refer to
specified, -capacity cannot be specified.
Optional. This parameter specifies the total capacity of the disks that are used to create a RAID
group. This parameter can only be specified when "-rg-mode auto" is specified. The disk that
corresponds to the capacity is automatically set. When -capacity is specified, -disks cannot be
specified.
Optional. This parameter specifies the assigned controller (CM number) of the specified RAID
group. This parameter can only be specified when "-rg-mode manual" is specified. If "auto" is
specified, the fixed controller, which is calculated automatically by the system, is assigned. If
omitted, the "auto" mode is set.
For the ETERNUS DX80 S2/DX90 S2:
0
Controller module#0
1
Controller module#1
auto
Automatically (default)
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
pool_name
| -pool-name
capacity
]
20).
"1.2.3 Disk Syntax" (page
83
}
"1.2.5 Thin
19). When -disks is
P2X0-1030-09ENZ0