Summary of Contents for Fujitsu Eternus DX80 S2

  • Page 2 This page is intentionally left blank.
  • Page 3 Fujitsu would like to thank you for purchasing our ETERNUS DX80 S2/DX90 S2 Disk storage system. The ETERNUS DX80 S2/DX90 S2 Disk storage system is designed to be connected to a Fujitsu (PRIMEQUEST, PRIMERGY, or SPARC Enterprise) or other server.
  • Page 4: About This Manual

    This chapter describes the components of the ETERNUS DX80 S2/DX90 S2 Disk storage system. ● Chapter 2 Basic Operation This chapter explains how to turn on and off the ETERNUS DX80 S2/DX90 S2 Disk storage system and how to operate the FUNCTION button on the controller enclosure. ● Chapter 3 Setup...
  • Page 5 ETERNUS DX Disk storage system and/or to CAUTION other users and their property, if the ETERNUS DX80 S2/DX90 S2 Disk storage system is not used properly. This symbol indicates IMPORTANT information for the user to note when IMPORTANT using the ETERNUS DX80 S2/DX90 S2 Disk storage system.
  • Page 6: Additional Information

    ETERNUS DX80 S2/DX90 S2 Disk storage system: - Make sure to disconnect the power when cleaning. - Be careful that no liquid seeps into the ETERNUS DX80 S2/DX90 S2 Disk storage system when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS DX80 S2/DX90 S2 Disk storage system.
  • Page 7: Table Of Contents

    Data Encryption ....................41 Eco-mode ......................42 Data Management .................... 44 3.4.1 RAID Migration .......................... 45 3.4.2 Logical Device Expansion (LDE) ....................46 3.4.3 LUN Concatenation ........................46 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 8 Appendix A Event Notification Message List ...........90 Message Format ....................90 A.1.1 E-mail ............................90 A.1.2 Syslog............................92 A.1.3 SNMP ............................95 A.1.4 Host Sense ..........................99 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 9 Common Terms........................100 A.2.2 Error Messages ........................101 A.2.3 Warning Messages........................116 A.2.4 Informational Messages ......................126 A.2.5 Test Messages ........................131 A.2.6 Sense Codes ........................... 132 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 10 Positions of 3.5" drive slots......................54 Figure 5.3 Installation diagram for a host interface adapter (single-controller type)........76 Figure 5.4 Installation diagram for host interface adapters (dual-controller type)........77 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 11 Table 6.1 Time for volume formatting (disk) ....................79 Table 6.2 Rebuild process time (disk) ....................... 80 Table 6.3 Copyback process time (disk) ....................80 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 12: Chapter 1 Components

    3.5" type Operation panel 3.5" disk or 3.5" Solid State Drive (SSD) Flange cover Flange cover Figure 1.2 Front view of a 3.5" type controller enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 13: Rear

    ■ Dual-controller type Controller (CM#0) Controller (CM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) Figure 1.4 Rear view of a controller enclosure (dual-controller type) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 14: Components (Front)

    Without a flange cover POWER LED READY LED FAULT LED FUNCTION button MAINT/ID LED CACHE LED Power switch Figure 1.6 Operation panel (3.5" type controller enclosure) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 15: Figure 1.7 2.5" Drive

    There is data in the ETERNUS DX Disk storage (green) system cache memory. ■ Drives ● 2.5" drives DRIVE READY LED DRIVE FAULT LED Figure 1.7 2.5" drive ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 16: Figure 1.8 Drive Slot Numbers (2.5" Type Controller Enclosure)

    The drive is in error status. (orange) • In response to commands from Microsoft Virtual Disk Service (VDS) or ETERNUS CLI, the location of the drive is identified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 17: Components (Rear)

    • LAN (RMT) port, LAN (MNT) port These ports are RJ-45 connectors for LAN cables. LAN (RMT) port is not used in the EMEA&I region. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 18: Table 1.3 Status And Meanings Of Each Led (Controller)

    A host interface adapter is a board that has interface ports to connect a controller to the server. There are five types of host interfaces: FC, iSCSI 10Gbit/s, FCoE, iSCSI 1Gbit/s, and SAS. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 19: Figure 1.12 Host Interface Adapter (Fc, Iscsi 10Gbit/S, Fcoe)

    Installed host interface adapters in the controller Port#0 Port#1 Port#0 Port#1 Host interface adapter (CA#0) Host interface adapter (CA#1) Figure 1.13 Host interface adapter (iSCSI 1Gbit/s) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 20: Figure 1.14 Host Interface Adapter (Sas)

    If a power outage is detected, data in the cache memory is saved to the non-volatile memory in the controller using the SCU. The saved data is retained in the non- volatile memory indefinitely. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 21: Figure 1.15 Power Supply Unit

    AC power is supplied to the other power supply unit. The power supply unit or the (off) (orange) (orange) (orange) fan in the power supply unit is in error status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 22: Drive Enclosures

    3.5" disk or 3.5" Solid State Drive (SSD) DE-ID (drive enclosure number) display panel Flange cover Flange cover Figure 1.17 Front view of a 3.5" type drive enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 23: Rear

    This section describes LEDs, a DE-ID (drive enclosure number) display panel, and drives of the front of the drive enclosure. ■ DE-ID (drive enclosure number) display panel The DE-ID (drive enclosure number) of the drive enclosure is displayed. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 24: Figure 1.20 Leds On The Front Side Of The Drive Enclosure

    The drive enclosure is in error status. (orange) POWER The drive enclosure is operating normally. (green) ■ Drives ● 2.5" drives DRIVE READY LED DRIVE FAULT LED Figure 1.21 2.5" drive ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 25: Figure 1.22 Drive Slot Numbers (2.5" Type Drive Enclosure)

    The drive is in error status. (orange) • In response to commands from Microsoft Virtual Disk Service (VDS), the location of the drive is identified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 26: Components (Rear)

    The link between the DI (OUT) port and the (green) destination port has been established. DI (IN) LINKUP The link between the DI (IN) port and the source (green) port has been established. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 27: Figure 1.26 Power Supply Unit

    The power supply unit or the fan in (off) (orange) (orange) (orange) the power supply unit is in error status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 28: Power Distribution Units (For Regions Other Than Emea&I)

    (AC input cable). • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 29: Power Distribution Units (2U)

    This turns on and off the power distribution unit. • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 30: Figure 1.29 Power Distribution Unit For Dx80 S2/Dx90 S2 (Ac200-240V, 2U, Max 8 Enclosures Connection)

    This turns on and off the power distribution unit. • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 31: Chapter 2 Basic Operation

    For 1U power distribution unit Main line switch Figure 2.1 ON position (marked "|") of the main line switches on a 1U power distribution unit ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 32: Figure 2.2 On Position (Marked "|") Of The Main Line Switches On A 2U Power Distribution Unit

    For 1U power distribution unit Main line switch Figure 2.3 OFF position (marked "O") of the main line switches on a 1U power distribution unit ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 33: Figure 2.4 Off Position (Marked "O") Of The Main Line Switches On A 2U Power Distribution Unit

    OFF (marked "O"), turn it back to ON (marked "I") after the POWER LED of the power supply unit has turned off completely. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 34: Switching On And Off The Psu Switch On The Power Supply Unit

    AC power is supplied to a power supply unit. The POWER LED on the power supply unit blinks green. The fan revolves at high speed for about 30 seconds. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 35: Powering On

    Do not turn the main line switches of the power distribution units and the PSU switches on the ETERNUS DX Disk storage system to the OFF posi- tion. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 36 Press the Power switch of the controller enclosure. Drive enclosure Power switch Drive enclosure Controller enclosure The POWER LEDs on the controller enclosure and the drive enclosures are turned on. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 37: Powering Off

    Press and hold the Power switch of the controller enclosure for four seconds or more. Drive enclosure Power switch Drive enclosure Controller enclosure The READY LED of the controller enclosure is turned off. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 38: Using The Function Button

    Restoring the factory default settings (network environment settings and firewall settings) of the LAN ports The following procedure explains how to use the FUNCTION button. Procedure Remove the flange cover of the controller enclosure. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 39 Use the pin to push down the FUNCTION button for three seconds. The ETERNUS DX Disk storage system is not in maintenance status when the MAINT/ID LED is off. Attach the flange cover. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 40: Chapter 3 Setup

    To use the Thin Provisioning function, register the Thin Provisioning license in the ETERNUS DX Disk storage system and set up the Thin Provisioning function. For details on the usage and overview of Thin Provisioning, refer to "ETERNUS DX80 S2/DX90 S2 Disk storage system Overview".
  • Page 41: Thin Provisioning Setup

    Thin Provisioning Volumes (TPVs) cannot be encrypted individually. Rather, the encryption status of TPVs depends on that of the TPP to which the TPVs belong. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 42: Eco-Mode

    "Host I/O Monitoring Interval". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 43 Network Time Protocol (NTP) server in the date and time setting in ETERNUS Web GUI or ETERNUS CLI to set automatic adjustment of the date and time. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 44: Data Management

    Migrating to a RAID group with a different RAID level changes the RAID level of volumes. This is used to convert the RAID level of all the volumes belonging to a given RAID group. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 45: Raid Migration

    If the power is turned off or an electrical power outage occurs during RAID Migration, the process will simply continue when the power is restored. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 46: Logical Device Expansion (Lde)

    The ability to concatenate widely distributed free areas in the ETERNUS DX Disk storage system allows efficient use of the drive capacity. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 47 When a volume that is using ETERNUS SF AdvancedCopy Manager to run backups is expanded via LUN Concatenation, the volume will need to be registered with ETERNUS SF AdvancedCopy Manager again. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 48: Chapter 4 Operations

    ETERNUS DX Disk storage system of the previous Master CM’s are taken over by the new Master CM. Figure 4.1 LAN control (switching of the Master CM) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 49: 4.2 Monitoring Eternus Dx Disk Storage System Status

    Event notification and status display for the ETERNUS DX Disk storage system can be performed by ETERNUS CLI. When ETERNUS CLI is used, refer to "ETERNUS CLI User’s Guide". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 50: Led Status Check

    The status of the ETERNUS DX Disk storage system and the usage status of RAID groups, TPPs, and SDPs can be checked in the Overview screen of ETERNUS Web GUI. Figure 4.3 ETERNUS Web GUI screen ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 51: Event Notification

    The methods that can be used to notify an event are "e-mail", "SNMP Trap", "syslog", "remote support", and "host sense". Note that REMCS is not available in the EMEA&I region. For the procedure on setting event notification, refer to "ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-".
  • Page 52: Figure 4.4 Event Notification

    (host) center REMCS/SNMP (*1) ETERNUS DX Disk storage system *1: SNMP for the EMEA&I region and REMCS for all other regions Figure 4.4 Event notification ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 53: Chapter 5 Installing Optional Products

    Do not uninstall or move a drive that is already installed. Contact your sales representative or maintenance engineer if a drive needs to be uninstalled or moved. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 54: Installation Rules For Drives

    3.5" drive slots. Slot#11 Slot#8 Slot#9 Slot#10 Slot#4 Slot#5 Slot#6 Slot#7 Slot#0 Slot#1 Slot#2 Slot#3 Figure 5.2 Positions of 3.5" drive slots ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 55: Installable Drives

    To avoid this, allow the packed drive sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 56 Do not stack drives or stand drives on end. • Do not apply external force to the interface connectors. • Do not knock or drop the drives on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 57: Additional Drive Installation Procedure

    Push into the tab of the dummy drive unit and pull it straight out of the drive slot. Dummy drive unit The removed dummy drive unit should be retained for future use. IMPORTANT ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 58 Check that the newly installed drive's DRIVE READY LED lights up green. Repeat Step 3 Step 4 for each additional drive. Remove the wrist strap. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 59 The removed dummy drive unit should be retained for future use. IMPORTANT Install the new drive. Press the catch on the drive lock lever to unlock it. Catch Lock lever ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 60 Set up RAID groups, volumes, hot spares, and Host Affinity settings on the new drives, as required. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 61: Installing Drive Enclosures

    At time of purchase, the installable drive enclosure model may be different from those described. To find the web-site to check the latest version of this manual, refer to "Read Me First". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 62: Drive Enclosure Handling Instructions

    Do not handle the drive enclosure roughly or subject it to physical shocks when laying it down. • Do not stack the drive enclosures. • Do not knock or drop the drive enclosure on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 63: Drive Enclosure Rack Installation Procedure

    The M5 centering screws should be inserted in the 1st and 6th holes above the base line of the controller enclosure. 2U rack rail M5 Centering screws (10mm) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 64 (M5 cage nut) (M5 cage nut) 1st position 1st position (M5 pan head screw) (M5 pan head screw) Base line of drive enclosure Rack rails ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 65 Rack rail (for left side) (Rear rack pillars) Washers M5 screws M5 screws Washers Washers (Front rack pillars) M5 screws Rack rail (for right side) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 66 Failure to do so may cause injury. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 67 Use two M5 screws to fasten it in the rack. ■ For regions other than EMEA&I Use four M5 screws to fasten it in the rack. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 68 The DE_No. labels are supplied with the ETERNUS DX Disk storage system. Attach the flange cover that is provided with the ETERNUS DX Disk storage sys- tem. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 69 3.5" type 2.5" type drive enclosure drive enclosure Bracket Thumb screw Repeat this procedure to install more drive enclosures in the rack. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 70: Additional Drive Enclosure Installation

    The [Add Drive Enclosure] screen appears. Check the DE-ID (drive enclosure number) for the drive enclosure that is to be added in "Target Drive Enclosure", and click the [Next] button. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 71 The following figures show the connection paths for QSFP cables when drive enclosure 1 is added. • For a single-controller type DI (IN) port Drive enclosure 1 (Added drive enclosure) Controller enclosure DI (OUT) port ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 72 When connecting QSFP cables, check the connector orientation and then firmly push it all the way in. When disconnecting QSFP cables, use the pull-tab to extract the connector. Pull-tab ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 73 The following figure shows an example of attaching destination labels on the QSFP cables that connect the controller enclosure to drive enclosure 1. Drive enclosure 1 (Added drive enclosure) Controller enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 74 The power cords must be connected to the inlets of both power supply units. Connect the power cord plugs to the inlets of the power supply units. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 75 Step Install the drives. For details on drive installation, refer to "5.1.4 Additional Drive Installation Procedure" (page 57). Remove the wrist strap. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 76: Installing Host Interfaces

    Contact your sales representative or maintenance engineer if a host interface needs to be uninstalled or moved. • Contact your maintenance engineer when a host interface adapter is installed in the channel adapter (CA#1) of the ETERNUS DX80 S2/ DX90 S2. 5.3.1 Installation Rules for Host Interfaces This section explains the installation rules for host interfaces.
  • Page 77: Installable Host Interfaces

    To avoid this, allow the packed host interface adapter sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 78 • Do not put anything on the host interface adapter. • Do not knock or drop the host interface adapter on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 79: Chapter 6 Maintenance

    The value shows the time required for volume formatting when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 80: Rebuild/Copyback Process Time

    The value shows the copyback process time when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 81: Maintenance Service

    If a possible error that may occur is detected or an error occurs when remote support service is used, the contents of events are automatically sent to the remote support center and notified to the user. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 82: Chapter 7 Troubleshooting

    Has there been a recent main power failure? If the Power Resume function is enabled, the ETERNUS DX Disk storage system turns on automatically after the power is restored. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 83 2 Connect the QSFP cable while the drive enclosure is on. 3 Press the controller enclosure’s Power switch to turn on the ETERNUS DX Disk storage system. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 84 In the details screen for each component, check the detailed information for each component with a and contact your maintenance engineer. When checking the general status via ETERNUS CLI, refer to "ETERNUS CLI User’s Guide". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 85 IMPORTANT for all of the LAN ports are initialized after the following procedure is per- formed. Procedure Remove the flange cover of the controller enclosure. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 86 • To use the SNMP Manager, enable the SNMP connection. If not, the ETERNUS DX Disk storage system does not respond to SNMP access. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 87 I/Os are issued for the appropriate number. For details on the number of command queues, refer to "ETERNUS DX Disk storage systems User's Guide -Server Connection-". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 88: Required Information For Inquiries

    ETERNUS CLI ("show enclosure-status" command) CLI> show enclosure-status Enclosure View Name [ETERNUS DX90 S2] Model Upgrade Status [Not Possible] Model name Model Name [ETxxxxxx] Serial Number [xxxxxxxxxx] Serial number ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 89 Disk storage system, obtain the required log/dump information using the log/dump collection function of ETERNUS Web GUI. Refer to "ETERNUS Web GUI User’s Guide" for how to obtain this information. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 90: A.1 Message Format

    The Severity of the event is displayed. One of the following items is displayed for the message: Error: indicates an error Warning: indicates a warning Information: indicates that information is provided Test: indicates a test mail ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 91 The year is display with four digits. The detailed information of the event is displayed. For multiple process results, each process result is displayed on a separate line. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 92: Syslog

    6: Informational For the "RFC3164" format, the HEADER part follows the PRI part. For the "RFC5424" format, "1" and then a blank follow the PRI part. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 93 ETERNUS DX Disk storage system is output in the following format: xxx.xxx.xxx.xxx The IPv4 address is output based on the "IETF STD13, RFC 1035" specification. A blank follows this item. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 94 For multiple process results, each process result is enclosed by brackets. Refer to "A.2 Message List" (page 100) for details. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 95: Snmp

    Trap No. 5 returns to normal status. fjdarye100SensorStatusChangeToNormal This Trap is sent to notify that an event notified by Trap No. 6 returns to normal status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 96 [2]:snmpTrapOID coldStart The operation time of 1.3.6.1.6.3.1.1.5.1 the SNMP Agent (centiseconds) The operation time is authenticationFailure 1.3.6.1.6.3.1.1.5.5 reset when the SNMP Agent starts or restarts. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 97 TRAP No. Information [3]:fjdaryTrapMessage Information [4]:fjdaryTrapWarningInfo 26 fjdarye100 Notification of Information [1]:fjdaryTrapItemId SensorStatus alarm cancel Information [2]:fjdarySspMachineId ChangeTo for TRAP No. Information Normal [3]:fjdaryTrapSensorInfo Information [4]:fjdaryTrapMessage ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 98 Information [3]:fjdaryTrapMessage Information [4]:fjdaryTrapWarningInfo 26 fjdarye100 Notification of 1.3.6.1.4.1.211.4.1.1. Information [1]:fjdaryTrapItemId SensorStatus alarm cancel for 126.1.100.0.26 Information [2]:fjdarySspMachineId ChangeToNormal TRAP No. 6 Information [3]:fjdaryTrapSensorInfo Information [4]:fjdaryTrapMessage ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 99: Host Sense

    ETERNUS Web GUI or ETERNUS CLI. For details on the sense code that is notified to the server, refer to "A.2.6 Sense Codes" (page 132). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 100: Message List

    Meaning Hot spares Thin Provisioning Volume(s) Thin Provisioning Pool SMART Self-Monitoring Analysis and Reporting Technology Firmware Hard Disk Drive Solid State Drive Direct Memory Access ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 101: Error Messages

    MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 102 CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) v: EXP number (0) p: Port number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 103 MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 104 CA type m: CM number (0 – 1) P: Port number (0 – 1) pp...: Component number ss...: Serial number rr...: Version oo...: Additional information ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 105 Port number (0 – 1) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 106 Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 107 Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 108 Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 109 Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 110 Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 111 Error uu: DE-ID ("00" for a controller enclosure) Severity Level in the event notifica- tion setting. They are not notified during mainte- nance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 112 REC HALT 0 (Path error) • REC HALT 1 (High load) • REC HALT 2 (Error) These mes- sages are not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 113 CPU number in CM enabled for Error Severity Level in the event notifi- cation setting. They are not noti- fied during main- tenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 114 System Disk) The device is in Not Ready status. Configuration information is restored using the backup area due to the replacement of a CM (including BUD). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 115 M E8050xxx E8050xxx TPP#xxx was all allocated tenance Usage status of the Thin Provisioning Pool is changed: operations. Warning to Caution xxx: TPP number (hexadecimal) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 116: Warning Messages

    MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 117 EXP number (0) p: Port number (0) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 118 S: CA slot number (0 – 1) V: Device number (0 – 1) zz: CA type m: CM number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 119 CE intake temperature error (Warning) is enabled for detected. Warning Level in the event notification setting. They are not notified during mainte- nance opera- tions. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 120 Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 121 Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 122 Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 123 Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 124 MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 125 PSU error is detected. SS: Component subtype uu: DE-ID ("00" for a controller enclosure) n: PSU number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 126: Informational Messages

    I 01000020 User &a Logged out from &b (&c) — Logged out from the device. &a: User name &b: IP address &c: GUI or CLI ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 127 &b: Slot number setting. &c: Type (Global or Dedicated) &d: RAID group number (only for Dedicated Hot Spares) &e: RAID group name (only for Dedicated Hot Spares) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 128 Snap Data Pool (encrypted) usage rate exceeds the threshold (Level1) $a% and reaches $b%. $a: Threshold of Snap Data Pool $b: Usage rate of Snap Data Pool ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 129 The trial license (local copy) has expired I 00000016 The trial license(Remote Copy) has expired. Detail information is not displayed. The trial license (remote copy) has expired. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 130 CE or DE. the event notifica- tion setting. This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 131: Test Messages

    Slot#0 in CE is in Fault status. A drive is not actually disconnected when a test Trap is notified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
  • Page 132: Sense Codes

    "Sensor (Temperature) Error" or "Parts error" is enabled for Error Severity Level in the event notification setting. They are not notified during mainte- nance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 133 Error Severity Level in the Rebuilding to a drive is complete. event notification setting. They are not notified during Copyback starts. maintenance operations. Copyback is complete. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 134 DE port error is detected. Level in the event notification setting. DE QSFP port error is detected. They are not notified during mainte- nance operations. PSU error is detected. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 135 "Sensor (Temperature) warning" is DE intake temperature error is detected. enabled for Warning Level in the event notification setting. They are not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
  • Page 136 • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. •...