Chapter 4 Function/System Settings and Display
4.3 Network Management > set lcd-suppress

set lcd-suppress

This command sets up LCD suppression (whether the error display for the components is displayed on the
LCD). This command can only be used for the ETERNUS DX8700 S2.
Syntax
set lcd-suppress [-parts-error {enable | disable}] [-parts-warning {enable | disable}]
[-disk-error {enable | disable | disable-when-no-hs }]
[-disk-warning {enable | disable | disable-when-no-hs }]
Parameter
-parts-error Optional. This parameter is specified to suppress the error display for the components (other
-parts-warning
-disk-error
-disk-warning
than drives) on the LCD display. If omitted, the setting is not changed.
enable
Error display suppression is set for the components (other than drives).
disable
Error display suppression is canceled for the components (other than drives).
Optional. This parameter is specified to suppress the warning display for the components
(other than drives) on the LCD display. If omitted, the setting is not changed.
enable
Warning display suppression is set for the components (other than drives).
disable
Warning display suppression is canceled for the components (other than drives).
This parameter is specified to suppress the error display for the drives on the LCD display.
Optional. If omitted, the setting is not changed.
enable
Error display suppression is set for the drives. The error display is suppressed
regardless of the number of hot spares left.
disable
Error display suppression is canceled for the drives. The error display is not
suppressed regardless of the number of hot spares left.
disable-when-no-hs
Error display suppression is set for the drives when a hot spare exists. Disk error
is displayed when no hot spares are left.
This parameter is specified to suppress the warning display for the drives on the LCD display.
Optional. If omitted, the setting is not changed.
enable
Warning display suppression is set for the drives. The warning display is
suppressed regardless of the number of hot spares left.
disable
Warning display suppression is canceled for the disks.
disable-when-no-hs
Warning display suppression is set for the drives when a hot spare exists. Disk
warning is displayed when no hot spares are left.