Chapter 4 Function/System Settings and Display
4.2 Advanced Copy Management > set host-port-mode

set host-port-mode

This command sets which mode to use for host interface ports.
Host interface ports used to REC functions must be switched to RA mode or CA/RA auto mode.
When switching to RA mode or CA/RA auto mode, all host mapping information associated with the port
is lost.
When reverting to CA mode, all REC path information defined for the port is lost.
When the port mode is switched from the RA mode or the CA/RA auto mode to another mode, the REC
transfer mode setting (Consistency/Stack/Through/Sync) of the port is changed to the default value
("enable" for all of the setting).
When the port mode is switched from the RA mode to the CA/RA auto mode or vice versa, the REC transfer
mode setting (Consistency/Stack/Through/Sync) of the port is retained.
When the port mode is switched from the RA mode or the CA/RA auto mode to another mode, the line
number (REC Line No.) setting of the port is changed to the default value (0).
When the port mode is switched from the RA mode to the CA/RA auto mode or vice versa, the line number
(REC Line No.) setting for the port is retained.
Syntax
set host-port-mode -port {xyz|all} -mode {ra|ca|cara|initiator}
Parameter
-port
-mode
This parameter specifies the number of the host interface port that is to be switched. Two or
more parameters can be specified by separating them with a comma.
Example: -port 000,100
For details, refer to
"1.2.14 Host Interface Port Syntax" (page
xyz
"x" is the controller module (CM) number, "y" is the CA number, and "z" is the host
interface port number.
Example: "123" indicates CM#1 CA#2 port#3
all
All the host interface ports
Optional. This parameter specifies operation mode for the host interface port. RA mode must
be set when the REC functions are used. The RA mode can only be set for FC ports and iSCSI
ports. The Initiator mode can only be set for FC ports.
ra
RA mode (for REC)
ca
CA mode
initiator
Initiator mode (for Storage Migration)
cara
CA/RA auto mode
ETERNUS CLI User's Guide