Process - Toshiba e-STUDIO2820C Service Handbook

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2820C:
Table of Contents

Advertisement

2.5.3

Process

Classifi-
Code
cation
400
Fuser
Fuser unit error status
counter
556
Image
Image quality closed-loop
control
control/Contrast voltage
557
Image
Image quality closed-loop
control
control/Laser power
573
Image
Abnormality detection
control
count (Y)
Display/0 clearing
574
Image
Abnormality detection
control
count (M)
Display/0 clearing
575
Image
Abnormality detection
control
count (C)
Display/0 clearing
576
Image
Abnormality detection
control
count (K)
Display/0 clearing
© 2008 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Func-
<Accept-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2 - 73
Default
RAM
Contents
able
value>
0
M
0: No error
<0-51>
7: C467
24: C446
31: C4D0
1
M
Sets whether or not cor-
<0-1>
recting the contrast volt-
age in closed-loop
control.
0: Invalid
1: Valid
1
M
Sets whether or not cor-
<0-1>
recting the laser power
in closed-loop control.
0: Invalid
1: Valid
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
e-STUDIO2820C/2830C/3520C/3530C/4520C
Pro-
cedur
e
1
1
1
1
1
1
1
SELF-DIAGNOSTIC MODE
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio3530cE-studio4520cE-studio2830cE-studio3520c

Table of Contents