[E860] RADF jam access cover open
1. Close the RADF jam access cover if it is opened. Remove if there is any original before closing it.
2. Is the RADF jam access cover switch working? (Perform the input check: 03-[FAX]ON/[7]/[C])
* If it is working properly, proceed to 6. If not, check 3 to 5 below.
3. Check if the connector CN8 on the RADF board is disconnected from the RADF jam access
cover switch or the harnesses are open circuited. Correct if any.
4. Replace the RADF jam access cover switch.
5. Replace the RADF board.
[E870] RADF open jam
1. Close the RADF if it is opened. Remove if there is any original before closing it.
2. Is the RADF opening/closing sensor working? (Perform the input check: 03-[FAX]ON/[7]/[D])
* If it is working properly, proceed to 6. If not, check 3 to 5 below.
3. Check if the connector CN75 on the RADF board is disconnected from the RADF opening/clos-
ing sensor or the harnesses are open circuited. Correct if any.
4. Replace the RADF opening/closing sensor.
5. Replace the RADF board.
6. Is the RADF opening/closing sensor adjusted within the specified range?
e-STUDIO2820C/2830C/3520C/3530C/4520C
ERROR CODE AND TROUBLESHOOTING
© 2008 TOSHIBA TEC CORPORATION All rights reserved
6 - 40