Procedure For Disabling Data Encryption Function - Toshiba e-STUDIO2820C Service Handbook

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2820C:
Table of Contents

Advertisement

[I]
Check actuation of data encryption function setting
Check if the data encryption function is in operation.
Press the [USER FUNCTION] button on the control panel. If a key-shaped icon is displayed at the
top right of the screen, the data encryption function is in operation.
4.2.4

Procedure for disabling data encryption function

The basic procedure is the same as the one for enabling this function. To disable it, set "0 (Invalid)" in
the code 08-9379 at step
4.2.5
Procedure for discarding HDD when data encryption function is
enabled
Set the data encryption function disabled following the procedure shown in
for disabling data encryption function". Then perform the code 08-1426 (Forcible HDD data clearing) to
completely erase the data in the HDD.
© 2008 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-14
P.4-14 "[D] Enable data encryption function".
4 - 17
P.4-17 "4.2.4 Procedure
e-STUDIO2820C/2830C/3520C/3530C/4520C
BACKUP FUNCTION