5.6

Storage of Supplies and Replacement Parts

Precautions for storing supplies and replacement parts are shown below.
1. Toner/Developer
Toner and developer should be stored in a place where the ambient temperature is between 10°C to
35°C (no condensation), and should also be protected against direct sunlight during transportation.
2. Photoconductive drum
Like the toner and developer, photoconductive drum should be stored in a dark place where the
ambient temperature is between 10°C to 35°C (no condensation). Be sure to avoid places where
drums may be subjected to high humidity, chemicals and/or their fumes.
3. Drum cleaning blade / Transfer belt cleaning blade
This item should be stored in a flat place where the ambient temperature is between 10°C to 35°C,
and should also be protected against high humidity, chemicals and/or their fumes.
4. Transfer belt / Transfer roller / Fuser belt / Pressure roller
Avoid places where the rollers may be subjected to high humidity, chemicals and/or their fumes.
5. Paper
Avoid storing copy paper in places where it may be subjected to high humidity.
After a package is opened, be sure to place and store it in a storage bag.
© 2008 TOSHIBA TEC CORPORATION All rights reserved