5.5.1

Scanner

A2
Items to check
A1
Original glass
A2
ADF original glass
A3
Mirror-1
A4
Mirror-2
A5
Mirror-3
A6
Reflector
A7
Lens
A8
Exposure lamp
A9
Automatic original detection
sensor
A10
Slide sheet
(front and rear)
* A1: Original glass, A2: ADF original glass
Clean both sides of the original glass and ADF original. Make sure that there is no dust on the
mirrors-1, -2, -3 and lens after cleaning. Then install the original glass and ADF original glass.
Note:
Make sure that there is no fingerprints or oil staining on part of the original glass on where the
original scale is mounted since the shading correction plate is located below the scale to be
scanned.
e-STUDIO2820C/2830C/3520C/3530C/4520C
PREVENTIVE MAINTENANCE (PM)
A4
A8
A6
A5
A3
A9
Fig. 5-8
Lubri-
cation/
Cleaning
Coat-
ing
B or A
B
B
B
B
B
B
B
B or A
5 - 10
A1
A10
A7
Replacement
(x 1,000
(x 1,000 drive
sheets)
counts)
R
R
R
R
© 2008 TOSHIBA TEC CORPORATION All rights reserved