CE71 error can be prevented by setting the drum phase adjustment control OFF in the self-
diagnostic code below.
The setting value shall be returned after the recovery, otherwise color deviation increases.
Drum phase adjustment control ON/OFF code
08-4766
0: Disabled
1: Enabled (Default)
© 2008 TOSHIBA TEC CORPORATION All rights reserved