Sony DSR-570WS Service Manual page 88

Digital camcorder
Hide thumbs Also See for DSR-570WS:
Table of Contents

Advertisement

[||]
[||]
[||]
[||] is the factory setting
[||]
MENU
MENU
No.
DESCRIPTION
101
201
HOURS METER
DISPLAY
204
FRAME MODE
SELECTION
For DSR-570WS
(UC)
206
BATTERY
REMAINDER
DISPLAY
SELECTION
207
STANDBY TIMER
SETTING
210
AUTO CHECK
FUNCTION
SETTING
211
CLIP LINK
FUNCTION
SETTING
212
AUDIO
RECORDING
MODE SETTING
. For details on the USER MENU, refer to the Operating Instructions.
. Buttons used: RESET → RESET (MENU SET) button, ADV. → ADVANCE button, MENU → MENU button, SHIFT
→ SHIFT button.
4-2
DISPLAY WINDOW (LCD)
dF /ndF
AUto /nIcd/LI/Antn/nl-H
01/03/05/ 08
oFF /on
on /oFF
48 /32
BUTTON
CONTENTS
USED
ADV.
Sets the calendar and clock.
SHIFT
Use the SHIFT button to move between the digits to be set.
(Year → Month → Day → X0 Hours → 0X Hours → X0
Minutes → 0X Minutes → X0 Seconds → 0X Seconds →
Year)
SHIFT
Displays how long the head drum was used, how long the
tape was driven, and operating time in order.
A: How long the head drum was used
b: How long the tape was driven
C: Operating time (When power is turned ON)
*Each time Menu No. 201 is displayed and the SHIFT button
is pressed, the display changes in the following order.
(201 → A → b → C → 201)
ADV.
Selects the time code generator drop frame mode and non-
drop frame mode
dF:
Drop frame mode
ndF: Non drop frame mode
ADV.
Sets/switches the battery remainder display.
AUto: The kind of the battery is automatically distinguished.
nlcd: Nickel-cadmium battery (NP-1B, BP-90A)
LI:
Lithium ion battery (BP-L40/L60/L60A/L90/L90A)
Antn: Anton battery
nl-H: Nickel-hydrogen battery (BP-M50/M100)
ADV.
Sets the time for releasing the standby mode.
Can be selected from one minute, 3 minutes, 5 minutes, and
8 minutes.
ADV.
Automatically inspects if there are any problems in the basic
operations of this unit, connections between this unit and the
camera before starting to shoot.
When oFF is displayed: When the RESET button is pressed,
When on is displayed:
ADV.
Setting when the clip link shooting is not executed.
on:
Clip link function ON
oFF: Clip link function OFF
ADV.
Sets audio signal recording mode
48: 48 kHz 2 channel mode
32: 32 kHz 4 channel mode (Records CH-1, CH-2 only)
auto check is not performed, and
instead, Menu No. is displayed
again.
When the RESET button is pressed,
auto check is started. After auto
check is complete, press the MENU
button to exit from the menu mode.
DSR-570WS/570WSP V1