3. Press the RESET (MENU SET) button once.
Check that the following message will be displayed on
the display window (LCD).
If "no" is displayed on the display window (LCD), exit
from Menu No. 752 once, and perform the above
procedure again. If the display does not change, check
if the peripheral circuits of EEPROM (IC204) of the
FP-118A board are abnormal, and replace with the
EEPROM attached to the old board.
4. Press the MENU button to exit from the maintenance
menu. The display window (LCD) will return to the
state before the maintenance menu was displayed.
2-18-5. Adjustment and Setting Items After Boards are Replaced
When the following boards are replaced, implement the specified adjustments and checks.
The boards that are specified below do not require adjustments and checks when they are replaced.
Board
Adjustment and setting items
CCD unit
Camera System Electrical Alignment
Memory Backup
DPR-141B
Memory Backup
Serial Setting
VA EEPROM (SY) Initialize
ES-26/26P
Memory Backup
FP-118A
KY EEPROM Echo Back Data Preset
HN-227
Replace the IC1
RP-91
AUTO EQ Adjustment
TG-204
Input the CCD block number
DSR-570WS/570WSP V1
Menu items
—
Service menu Page 21
Service menu Page 21
System setting menu No. 52
Maintenance menu No. 750
Service menu Page 21
Maintenance menu No. 752
—
Maintenance menu No. 704
Service menu Page 13
Section to be
referred to
9-1-4
4-2-3
4-2-3
4-1-2
4-1-3
4-2-3
2-18-4
4-1-3
2-9-9
4-1-3
10-3-4
4-2-3
2-47