7-1-3. Tape Path Adjustment
Preparations
(1) Cassette Compartment
Attach the cassette compartment when
performing tape path adjustments. This will
enable adjustments to be performed more
accurately.
(2) Cleaning
Clean faces that are in contact with tape. For how
to clean them, refer to Section 5-4.
7-1-4. Connection
RF extension tool
Tool which can extract signals output from
connector CN775 of the RP-91 board and can be
connected easily to the probe.
Insert the RF extension tool board into CN775 of the
RP-91 board.
7-2
RF extension tool (Back)
JSW
RF
GND
CN775
RP-91 board
DSR-570WS/570WSP V1