7. Attach the GL (S) assembly to the attaching
shaft.
n
Adjust the protrusion of the GL (S) assembly to the
V groove of the GL (T) assembly as shown in the
figure, and attach the threading gear so that the
phase mark of the threading gear and teeth A next to
part B match.
8. Attach rail (S) first from the claw and then the
attaching shaft, and tighten the screw.
. Tightening torque: 0.0588 N.m (0.6 kg.cm)
9. Attach the capstan motor and drum assembly in
the reverse order of steps 1 and 2.
Check/Adjustment
10. Perform the capstan FG DUTY adjustment at
Menu M601. (Refer to Section 10-2-1.)
11. Perform the tracking adjustment.
(Refer to Section 7-3.)
12. Perform the check after tracking adjustment.
(Refer to Section 7-4.)
13. Perform the check of self-recording tape
playback. (Refer to Section 7-5.)
14. Perform the switching position adjustment at
Menu M605. (Refer to Section 7-6.)
6-24
Teeth A
Phase mark
Part B
GL (S) assembly
Threading gear
Screw
Rail (S)
Protrusion
V groove
GL (T) assembly
Claw
Attaching shaft