Sony DSR-570WS Service Manual page 169

Digital camcorder
Hide thumbs Also See for DSR-570WS:
Table of Contents

Advertisement

8. Remove the setscrew (3 x 4) to remove the filter
knob.
9. Remove the four screws (B3 x 8) and spring
washers, and remove the CCD unit from the
Front unit assembly.
n
When handling the CCD unit, pay attention not
to stress each PA board.
10. First remove the holder for transportation from
the replacement CCD unit.
Then replace the defective CCD unit with it.
n
Re-use the holder for shipping back the
replacement unit.
Attachment
11. Assemble in the reverse order of removal.
Adjustment
12. After the replacement is completed, perform
several adjustments referring to Section 9-1-4.
Note on Adjustment.
In addition, perform MEMORY BACK UP
referring to Service menu "Page 21" in Section
4-2-3.
DSR-570WS/570WSP V1
CCD unit
3Øspring washer
B3 x 8
B3 x 8
3Øspring washer
Transportation holder
Shield case
Setscrew
3 x 4
Filter knob
CCD unit
6-51