10.17 Internet Isw; Internet Isw Set; Http Setting - Konica Minolta bizhub C353 Service Manual

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

Field Service Ver. 4.0 Jun. 2008

10.17 Internet ISW

• By using this setting, the firmware stored in the server can be downloaded over internet
for upgrading.
• For details for upgrading the firmware, refer to "Firmware upgrade" in the Maintenance
section.
See P.48
10.17.1

Internet ISW Set

Functions
• To set whether or not to enable each setting for Internet ISW.
Use
• To use when upgrading the firmware by Internet ISW.
• Each setting such as Server setting will be valid by setting this to "ON".
NOTE
• When the following setting is set to "ON", this setting will automatically be set
to "OFF" and cannot be changed.
[Administrator Settings] → [Security Settings] → [Enhanced Security Mode]
Setting/
• The default setting is OFF.
Procedure
10.17.2

HTTP Setting

• It will be displayed only when [Internet ISW Set] is set to "ON".
A. Data Input Setting
Functions
• To set whether or not to enable downloading using the HTTP protocol.
Use
• To use when accessing the server using the HTTP protocol.
• Setting on the proxy server will be valid when this setting is "ON".
Setting/
• The default setting is OFF.
Procedure
B. Connect Proxy
Functions
• To set whether or not to connect via proxy server when accessing the server.
Use
• To use when accessing the server via proxy server.
Setting/
• The default setting is OFF.
Procedure
C. Proxy Server
Functions
• To set the address and the port number for the proxy server.
Use
• To use when accessing the server via proxy server.
Setting/
<Server Address>
Procedure
• Enter an address using IPv4, IPv6, or FQDN format.
<Port Number>
• Enter the value between 1 and 65535 using the 10-key pad.
(The default setting is 80)
ON
ON
ON
10. Service Mode
"OFF"
"OFF"
"OFF"
433

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub c253Bizhub c203

Table of Contents