18.3 Solution; Scanner System: White Lines In Sub Scan Direction, White Bands In Sub Scan Direction, Colored Lines In Sub Scan Direction, And Colored Bands In Sub Scan Direction - Konica Minolta bizhub C353 Service Manual

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

Field Service Ver. 4.0 Jun. 2008

18.3 Solution

NOTE
• Typical faulty image samples shown in the following are all printed with A4S set-
ting.
18.3.1
Scanner system: white lines in sub scan direction, white bands in sub
scan direction, colored lines in sub scan direction, and colored bands in
sub scan direction
A. Typical faulty images
White lines in sub
scan direction
B. Troubleshooting procedure
(1) When the original glass is used
Step
Section
1
Original
2
ADF
Original glass
3
Shading sheet
4
Mirror, lens,
exposure Lamp, and
5
reflectors
Machine → Scan
Area → Image Posi-
6
tion: Side Edge
(Service Mode)
7
White bands in sub
Color lines in sub
scan direction
scan direction
Check item
Original is damaged or dirty.
Original pad is dirty.
Original glass is dirty.
Shading sheet is dirty.
Mirror is dirty
Lens is dirty
Exposure lamp is dirty
Reflectors are dirty
The adjustment value for [Image
Position: Side Edge] falls within
the specified range.
The white lines/bands or colored
lines/bands are blurry.
18. Image quality problem
Color bands in sub
scan direction
A02EF4C507DA
Result
Action
YES
Change original.
YES
Clean.
YES
Wipe the surface clean with
a soft cloth.
YES
Wipe the surface clean with
a soft cloth.
YES
Clean.
YES
Clean.
YES
Clean.
YES
Clean.
NO
Readjust.
YES
Change scanner assy.
Change CCD unit.
559