2. Periodical check
[2]
[1]
[3]
[1]
12
5. Remove three screws [1] and
NOTE
• Remove the elevator motor assy
while holding the lower part of the
tray [3] with your hand.
[3]
A01GF2C561DA
NOTE
• Before reinstalling the elevator
[2]
motor assy, raise the tray [3] until
the lever [1] attached on the timing
belt moves to the position lower
than that of the sensor [2]. In that
state, reinstall the elevator motor
assy.
[1]
A01GF2C562DA
6. Remove the cover film [1] by peeling
A01GF2C563DA
Field Service Ver. 3.0 Jan. 2008
remove the elevator motor assy [2].
off its adhesive tape.