Bosch Video Management System
Crashing Configuration Client
Issue
Configuration Client crashes.
Crashing Operator Client
Issue
Operator Client crashes.
25.1

Configuring the desired language in Windows

If you want to change the display language for the setup of Bosch VMS, you must switch the
language in your Windows. For activating the language settings the computer is restarted after
performing the following steps.
To configure the desired language:
1.
2.
3.
4.
25.2

Reestablishing the connection to a Bosch IntuiKey keyboard

1.
2.
25.3

Reducing the number of Allegiant cameras

You need the Allegiant Master Control Software to edit the Allegiant file.
To reduce the number of Allegiant cameras:
1.
2.
3.
4.
5.
6.
7.
8.
Bosch Sicherheitssysteme GmbH
Click Start, click Control Panel, and then double-click Regional and Language Options.
Click the Advanced tab, under Language for non-Unicode programs, select the desired
language.
Click OK.
In each of the next message boxes, click Yes.
Your computer is restarted.
Plug in the cable again or wait until the workstation is online.
The Off Line message disappears.
Press the Terminal softkey to enter Bosch VMS.
Start the Master Control Software.
Open the Allegiant file.
Click the Camera tab.
Mark the cameras that are not required.
On the Edit menu, click Delete.
Save the file. The file size remains unchanged.
Repeat the last step for monitors that you do not need. Click the Monitors tab.
Import this file in Bosch Video Management System (see Adding a device, page 65).
Cause
If there are many cameras
configured in an Allegiant file
which are not connected to
Bosch Video Management
System, you can reduce this
number. This avoids
unnecessary system load.
Cause
DiBos Web client is installed
and has been started on the
computer where Operator
Client is installed.
Configuration Manual
Troubleshooting | en
Solution
See Reducing the number of
Allegiant cameras, page 235.
Solution
Uninstall the DiBos Web
client.