Bosch MBV-BPRO-45 Configuration Manual page 27

Video management system
Table of Contents

Advertisement

Bosch Video Management System
To enable the remote access of an Operator Client to devices in a remote network, each
device is assigned a public port number in addition to the public network address of the
router. For access, Operator Client uses this public port number together with the public
network address. In the private network the incoming traffic for the public port number is
forwarded to the private network address and port number of the corresponding device.
You configure the port mapping in Configuration Client for use by Operator Client.
Notice!
Additionally the network administrator must configure the port forwarding on the router of
i
the private network. The network administrator must ensure that remote access via these
ports is running outside of Bosch VMS environment.
Bosch Sicherheitssysteme GmbH
1
Firewall
2
Router
Port forwarding
3
Management Server
Port mapping
4
Operator Client
Logon to
5
Configuration Client
Logon to
6
7
8
9
10
Configuration Manual
Concepts | en
IP camera / encoder
Enterprise Management Server
Enterprise server list
Decoder
DynDNS Server
Dynamic naming
World Wide Web
2013.03 | V1 | Configuration Client