MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems Installation and Operation Manual...
Page 2
MIC-WKTI and MIC-WKT-IR Installation Manual EN | 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits for the MIC400 Camera Power Supply Units Installation and Operation Manual Chapters_______________________________________________ 1. Introduction 2. Installation Instructions 3. Technical Specifications Bosch Security Systems Issue 1...
14. Only use approved attachments or accessories specified by the manufacturer. Any changes or modifications made to the equipment, not expressly approved in writing CAUTION by Bosch Security Systems, could prevent proper or safe operation of the product TO REDUCE THE RISK OF ELECTRICAL SHOCK, and will invalidate the warranty.
Page 5
Pan/Tilt/Zoom LV Directive (73/23/EC) Power Supply Unit Infra Red Camset Bosch Security Systems configuration & set up software, RoHS (Restriction of Hazardous substances) 2002/95/EC please WEEE (Waste Electrical & Electronic Equipment) 2002/96/EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE).
MIC-WKTI and MIC-WKT-IR Installation Manual EN | 6 Introduction CHAPTER 1 The MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits provide the required fittings to enable third party washer kits to remotely clean the window of the MIC400 camera. Bosch Security Systems...
The following MIC400 Power Supply Units include 4 –Alarm inputs and a Washer The MIC-WKT-IR kit is identical to the MIC-WKT kit except for lacking the 705-200 Pump Drive function as standard and details of setting up the washer drive are...
If the unit must be returned, use the original packing materials. Packaging Contents Please check for the following contents for the MIC-WKT Washer Kit • MIC-WKT and MIC-WKT-IR Washer Kit Installation Manual (this Booklet) • 705-200 Washer Pump Drive Card • Single Jet Washer Nozzle (5mm) •...
Page 9
MIC-WKTI and MIC-WKT-IR Installation Manual EN | 9 Installation of the 705-200 Washer Pump Drive Card Figure 1:- MIC400 Non-IR Power Supply PCB Layout CAUTION: Electrical Danger: Ensure all power is disconnected before opening or working upon the MIC400 Power Supply Unit.
Power Supply Unit, leave sufficient slack to Installation must be carried out by suitably qualified persons connect to the SK1 terminal then tighten the gland. Bosch Security Systemsstrongly recommends that the washer pump power cable should be protected externally by a suitably rated fuse.
Page 11
To connect a washer pump to the IR power supply, please do the following:- CAUTION: Electrical Danger: Ensure all power is Bosch Security Systems Infra Red Power supplies have an integrated Washer disconnected before opening or working upon the MIC400 Pump Drive and 4 –...
Page 12
7. Tighten the weatherproof gland then connect the pump power cable to the appropriate terminals (Live or Neutral) taking care to observe the correct polarity as shown below. Bosch strongly recommends that the washer pump power cable should be protected externally by a suitably rated fuse.