"H" Group: Motor Constants Functions
3-8
"H" Group: Motor Constants Functions
Func.
Code
H001
Auto-tuning selection
H002
Motor parameter selection
H202
2nd motor parameter selection
H003
Motor capacity selection
H203
2nd motor capacity selection
H004
Motor pole number selection
H204
2nd motor pole number
selection
H005
Speed response
H205
2nd speed response
H006
Stabilization parameter
H206
2nd stabilization parameter
H020
Motor parameter R1
H220
2nd motor parameter R1
H021
Motor parameter R2
H221
2nd motor parameter R2
H022
Motor parameter L
H222
2nd motor parameter L
H023
Motor parameter Io
H223
2nd motor parameter Io
H024
Motor parameter J
H224
2nd motor parameter J
H030
Motor parameter R1
(auto-tuning data)
H230
2nd motor parameter R1
(auto-tuning data)
H031
Motor parameter R2
(auto-tuning data)
H231
2nd motor parameter R2
(auto-tuning data)
H032
Motor parameter L
(auto-tuning data)
H232
2nd motor parameter L
(auto-tuning data)
172
The "H" Group parameters configure the inverter for the motor characteristics.
You must manually set  and  values to match the motor. Parameter
 is factory-set. If you want to reset the parameters to the factory default
settings, use the procedure in 6-3 Restoring Factory Default Settings on page
279. Use  to select the torque control algorithm as shown in the diagram.
Please refer to 3-8-3 Auto-tuning Function on page 175 for detailed explana-
tion of the auto-tuning.
"H" Function
Name
Option codes:
... OFF (Disabled)
... ON (STOP)
... ON (Rotation)
Option codes:
... Standard motor parameter
... Auto tuning parameter
Selections: 0.1/0.2/0.4/0.75/1.5/
2.2/3.7/5.5/7.5/11/15/18.5
Selections: 2/4/6/8/10/12/14/16/
18/20/22/24/26/28/30/32/34/36/
38/40/42/44/46/48
Set range is 1 to 1000
Motor constant (factory set),
range is 0 to 255
0.001~65.535 ohms
0.001~65.535 ohms
0.01~655.35 mH
0.01~655.35 A
0.001~9999.000 kgm²
0.001~65.535 ohms
0.001~65.535 ohms
0.01~655.35mH
Run
Mode
Description
Edit
Section 3-8
Defaults
EU
Units
00
00
00
Specified by
kW
the capacity of
kW
each inverter
model
4
poles
4
poles
100
%
100
%
100
100
Depends on
Ohm
the motor
Ohm
capacity
Depends on
Ohm
the motor
v
capacity
Depends on
mH
the motor
mH
capacity
Depends on
A
the motor
A
capacity
Depends on
kgm²
the motor
kgm²
capacity
Ohm
Depends on
the motor
Ohm
capacity
Ohm
Depends on
the motor
Ohm
capacity
mH
Depends on
the motor
mH
capacity