Ambient Temperature Derating Curves - Omron 3G3MX2 User Manual

Mx2 series 200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

MX2 Inverter Specifications
3G3MX2-A4110
32
30
28
output current
26
24
22
20
0
2
4
Carrier frequency
3G3MX2-A2150
75
70
65
60
output current
55
50
45
0
2
4
Carrier frequency
3G3MX2-A4150
40
35
30
25
output current
20
15
10
0
2
4
Carrier frequency
Ambient Temperature Derating Curves (IP54)
For 11 kW and 15 kW MX2 inverters, the carrier frequency must be limited to
2 kHz maximum.
For all other MX2 inverter models, the curves for individual mounting (ambient
temperature 40°C max) are applicable.
CT (24.0 A)
32
30
28
26
24
22
20
6
8 10 12
14
16 kH
CT (60.0 A)
75
70
65
60
55
50°C individual
50
40°C side-by-side
45
6
8 10 12
14
16 kH
CT (31.0 A)
40
35
30
25
20
15
10
6
8 10 12
14
16 kH
Section 1-2
VT (31.0 A)
50°C individual
40°C side-by-side
0
2
4
6
8 10 12 14 kH
Carrier frequency
VT (69.0 A)
50°C individual
40°C side-by-side
0
2
4
6
8 10 12 14 kH
Carrier frequency
VT (38.0 A)
50°C individual
40°C side-by-side
0
2
4
6
8 10 12 14 kH
Carrier frequency
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents