Free-V/F Settings Related; Brake Control Function Related - Omron 3G3MX2 User Manual

Mx2 series 200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

"B" Group: Fine Tuning Functions
Func.
Code



3-6-20 Free-V/F Settings Related

Func.
Code















3-6-21 Brake Control Function Related

"B" Function
Name
Free-run stop selection
Stop mode selection
Please refer to chapter 3 for detailed explanation of the function.
"B" Function
Name
Free V/F frequency 1
Free V/F voltage 1
Free V/F frequency 2
Free V/F voltage 2
Free V/F frequency 3
Free V/F voltage 3
Free V/F frequency 4
Free V/F voltage 4
Free V/F frequency 5
Free V/F voltage 5
Free V/F frequency 6
Free V/F voltage 6
Free V/F frequency 7
Free V/F voltage 7
The brake control function allows you to make the inverter control an external
brake used for a lift or other machines. To enable this function, specify ""
(enabling the brake control function) for the Brake Control Enable (). This
function operates as described below.
1. When the inverter receives an operation command, it starts the output and
accelerates the motor up to the Brake Release Frequency Setting ().
2. After the Brake Release Frequency Setting is reached, the inverter waits
for the braking wait time (), and then outputs the brake release signal
(BOK). However, if the inverter output current has not reached the brake
release current (), the inverter does not output the brake release sig-
nal, but trips and outputs a brake error signal (BER).
3. When the braking confirmation signal (BOK) has been assigned to an in-
telligent input terminal (that is, when "" is specified for one of "" to
""), the inverter waits for the Brake Wait Time for Confirmation ()
without accelerating the motor after receiving the brake release signal. If
the inverter does not receive the braking confirmation signal within the
braking confirmation time (), it trips with the braking error signal (BER)
Description
Selects how the inverter resumes
operation when free-run stop
(FRS) is cancelled, three options:

0 Hz start

f-match (Frequency
matching start)

Actv. f-match (Active
Frequency Matching restart)
Select how the inverter stops the
motor, two option codes:

DEC (decelerate to stop)

FRS (free-run to stop)
Description
Set range, 0 ~ value of 
Set range, 0.0 ~ 800.0 V
Set range, value of  ~
Set range, 0.0 ~ 800.0 V
Set range, value of  ~
Set range, 0.0 ~ 800.0 V
Set range, value of  ~
Set range, 0.0 ~ 800.0 V
Set range, value of  ~
Set range, 0.0 ~ 800.0 V
Set range, value of  ~
Set range, 0.0 ~ 800.0 V
Set range,  ~ 400
Set range, 0.0 ~ 800.0 V
Section 3-6
Run
Defaults
Mode
EU
Units
Edit
00
00
Run
Defaults
Mode
EU
Units
Edit
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
147