"B" Group: Fine Tuning Functions
Func.
Code
3-6-20 Free-V/F Settings Related
Func.
Code
3-6-21 Brake Control Function Related
"B" Function
Name
Free-run stop selection
Stop mode selection
Please refer to chapter 3 for detailed explanation of the function.
"B" Function
Name
Free V/F frequency 1
Free V/F voltage 1
Free V/F frequency 2
Free V/F voltage 2
Free V/F frequency 3
Free V/F voltage 3
Free V/F frequency 4
Free V/F voltage 4
Free V/F frequency 5
Free V/F voltage 5
Free V/F frequency 6
Free V/F voltage 6
Free V/F frequency 7
Free V/F voltage 7
The brake control function allows you to make the inverter control an external
brake used for a lift or other machines. To enable this function, specify ""
(enabling the brake control function) for the Brake Control Enable (). This
function operates as described below.
1. When the inverter receives an operation command, it starts the output and
accelerates the motor up to the Brake Release Frequency Setting ().
2. After the Brake Release Frequency Setting is reached, the inverter waits
for the braking wait time (), and then outputs the brake release signal
(BOK). However, if the inverter output current has not reached the brake
release current (), the inverter does not output the brake release sig-
nal, but trips and outputs a brake error signal (BER).
3. When the braking confirmation signal (BOK) has been assigned to an in-
telligent input terminal (that is, when "" is specified for one of "" to
""), the inverter waits for the Brake Wait Time for Confirmation ()
without accelerating the motor after receiving the brake release signal. If
the inverter does not receive the braking confirmation signal within the
braking confirmation time (), it trips with the braking error signal (BER)
Description
Selects how the inverter resumes
operation when free-run stop
(FRS) is cancelled, three options:
0 Hz start
f-match (Frequency
matching start)
Actv. f-match (Active
Frequency Matching restart)
Select how the inverter stops the
motor, two option codes:
DEC (decelerate to stop)
FRS (free-run to stop)
Description
Set range, 0 ~ value of
Set range, 0.0 ~ 800.0 V
Set range, value of ~
Set range, 0.0 ~ 800.0 V
Set range, value of ~
Set range, 0.0 ~ 800.0 V
Set range, value of ~
Set range, 0.0 ~ 800.0 V
Set range, value of ~
Set range, 0.0 ~ 800.0 V
Set range, value of ~
Set range, 0.0 ~ 800.0 V
Set range, ~ 400
Set range, 0.0 ~ 800.0 V
Section 3-6
Run
Defaults
Mode
EU
Units
Edit
00
–
00
–
Run
Defaults
Mode
EU
Units
Edit
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
147