"A" Group: Standard Functions

3-5-14 Additional Analog Input Settings

Func.
Code





118
~ Curvature of EL-S-curve
When using EL-S-curve pattern, you can set the curvatures individually for
acceleration and deceleration. If all the curvatures are set to 50%, the EL-S-
curve pattern will be equivalent to the S-curve pattern.
A151
Curvature for
acceleration 2
0
For use of EL-S curve be sure to use select multi-speed as frequency source
to avoid nuisance change of frequency during acceleration and deceleration.
Input Range Settings - The parameters in the following table adjust the input
characteristics of the analog current input. When using the inputs to command
the inverter output frequency, these parameters adjust the starting and ending
ranges for the current, as well as the output frequency range. Related charac-
teristic diagrams are located in 3-5-2 Analog Input Settings on page 93.
Analog sampling setting is the value specified in .
"A" Function
Name
OI input active range start
frequency
OI input active range end
frequency
OI input active range start ratio The starting point (offset) for the
OI input active range end ratio
OI input start frequency enable Two options; select codes:
Refer to parameter  to  for analog voltage input.
Curvature for
A150
acceleration 1
Description
The output frequency correspond-
ing to the analog input range start-
ing point, range is 0.00 to 400.00
Hz
The output frequency correspond-
ing to the current input range end-
ing point, range is 0.00 to 400.00
Hz
current input range, range is 0 to
OI end ratio
The ending point (offset) for the
current input range, range is OI
start ratio to 100
... Start FQ (Use OI start
frequency [A101])
... 0 Hz
Section 3-5
Curvature for
A152
deceleration 1
Curvature for
A153
deceleration 2
t
Run
Defaults
Mode
EU
Units
Edit
0.00
Hz
0.00
Hz
20
%
100
%