Precautions for Safe Use

!Caution When using normally closed active state settings (C011 to C017) for exter-
!Caution In all the instrumentations in this manual, covers and safety devices are occa-
!Caution Do not discard the inverter with household waste. Contact an industrial waste
5
Precautions for Safe Use
xviii
nally commanded Forward or Reverse terminals [FW] or [RV], the inverter
may start automatically when the external system is powered OFF or discon-
nected from the inverter! So do not use normally closed active state settings
for Forward or Reverse terminals [FW] or [RV] unless your system design pro-
tects against unintended motor operation.
sionally removed to describe the details. While operating the product, make
sure that the covers and safety devices are placed as they were specified
originally and operate it according to the instruction manual.
management company in your area who can treat industrial waste without
polluting the environment.
Installation and Storage
Do not store or use the product in the following places.
• Locations subject to direct sunlight.
• Locations subject to ambient temperature exceeding the specifications.
• Locations subject to relative humidity exceeding the specifications.
• Locations subject to condensation due to severe temperature fluctuations.
• Locations subject to corrosive or flammable gases.
• Locations subject to exposure to combustibles.
• Locations subject to dust (especially iron dust) or salts.
• Locations subject to exposure to water, oil, or chemicals.
• Locations subject to shock or vibration.
Transporting, Installation and Wiring
• Do not drop or apply strong impact on the product. Doing so may result in
damaged parts or malfunction.
• Do not hold by the front cover and terminal block cover, but hold by the fins
during transportation.
• Do not connect an AC power supply voltage to the control input/output termi-
nals. Doing so may result in damage to the product.
• Be sure to tighten the screws on the terminal block securely. Wiring work
must be done after installing the unit body.
• Do not connect any load other than a three-phase inductive motor to the U, V,
and W output terminals.
• Take sufficient shielding measures when using the product in the following
locations. Not doing so may result in damage to the product.
Locations subject to static electricity or other forms of noise.
Locations subject to strong magnetic fields.
Locations close to power lines.
Operation and Adjustment
• Be sure to confirm the permissible range of motors and machines before opera-
tion because the inverter speed can be changed easily from low to high.
• Provide a separate holding brake if necessary.
• If the Drive Programming stops during multi-function output, the output status is
held. Take safety precautions such as stopping peripheral devices.
• If the clock command is used in Drive Programming, an unexpected operation
may occur due to weak battery. Take measures such as detecting a weak battery
by a check that the clock data returns to the initial setting and stopping the inverter
5