Output Terminal Configuration - Omron 3G3MX2 User Manual

Mx2 series 200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

"C" Group: Intelligent Terminal Functions
Option
Terminal
Code
Symbol

AHD

CP1

CP2

CP3

ORL

ORG

SPD

GS1 *

GS2 *

485

PRG

HLD

ROK

EB

DISP

UIO

PSET

no
3-7-3

Output Terminal Configuration

Func.
Code

Multi-function output terminal
11 selection

Multi-function output terminal
12 selection

Relay output (AL2, AL1)
function selection
158
Input Function Summary Table
Function Name
Analog command held
Position command
selection 1
Position command
selection 2
Position command
selection 3
Zero return limit signal
Zero return startup
signal
Speed/position
switching
GS1 input
GS2 input
Start EzCOM
Drive Programming
start
Retain output frequency ON
Permission of Run
command
Rotation direction
detection (C007 only)
Display limitation
Unprotected inverter
operation mode
Preset position
No allocation
The inverter provides configuration for logic (discrete) and analog outputs,
shown in the table below.
"C" Function
Name
48 programmable functions avail-
able for logic (discrete) outputs
(see next section)
48 programmable functions avail-
able for logic (discrete) outputs
(see next section)
Description
ON
Analog command is held
OFF
Analog command is not held
ON
Multistage position commands are set according to
the combination of these switches.
OFF
ON
OFF
ON
OFF
ON
Limit signal of homing is ON
OFF
Limit signal of homing is OFF
ON
Starts homing operation
OFF
No action
ON
Speed control mode
OFF
Position control mode
ON
EN60204-1 related signals. Signal input of "Safe
torque off" function
OFF
ON
OFF
ON
Starts EzCOM
OFF
No execution
ON
Executing Drive Programming
OFF
No execution
Retain the current output frequency
OFF
No retention
ON
Run command permitted
OFF
Run command is not permitted
ON
Forward rotation
OFF
Reverse rotation
ON
Only a parameter configured in b038 is shown
OFF
All the monitors can be shown
ON
Unprotected inverter operation mode is enabled
OFF
Unprotected inverter operation mode is disabled
ON
P083 value is set to current position
OFF
-
ON
(input ignored)
OFF
(input ignored)
Description
Section 3-7
Run
Defaults
Mode
EU
Units
Edit
00 [RUN]
01 [FA1]
05 [AL]