"D" Group: Monitoring Functions
3-3-34 PID Deviation Monitor [d153]
3-3-35 PID Output Monitor [d155]
It displays the PID deviation into d153 monitor. It only operates when PID
function is effective (A071=01 or 02).
Parameter
Function name
No.
d153

PID deviation monitor

A071
PID selection
A075
PID scale
d153 = PID deviation x PID scale (A075).
The display by digital operator is shown below:
Display
-999 to -100
-999. to -100.
-99.9 to -10.0
-9.99 to 99.99
100.0 to 999.9
1000. to 9999.
It displays the scaled PID output into d155 monitor. It is enabled only when
PID function is effective (A071=01 or 02).
Parameter
Function name
No.
d155

PID output monitor

A071
PID selection
A075
PID scale
d155 = PID output value x PID scale (A075).
Note: PID output value is a value limited by frequency limit (A061/A261) and
PID output limit (A078). Monitor d155 displays a value after a limit was set.
The display by digital operator is shown below:
Display
-999 to -100
-999. to -100.
-99.9 to -10.0
-9.99 to 99.99
100.0 to 999.9
1000. to 9999.
Data
-9999.00 to 9999.00
00: OFF (Disabled)
01: ON(+) (Enabled)
02: ON(+/-) (Reverse
output enabled)
0.01 to 99.99
Data
-9999.00 to -1000.00
-999.99 to -100.00
-99.99 to -10.00
-9.99 to 99.99
100.00 to 999.99
1000.00 to 9999.00
Data
0.00 to 9999.00
(A071=01)
-9999.00 to 9999.00
(A071=02)
00: OFF (Disabled)
01: ON(+) (Enabled)
02: ON(+/-) (Reverse
output enabled)
0.01 to 99.99
Data
-9999.00 to -1000.00
-999.99 to -100.00
-99.99 to -10.00
-9.99 to 99.99
100.00 to 999.99
1000.00 to 9999.00
Section 3-3
Default
Unit
setting
-
%
00
-
1.00
-
Default
Unit
setting
-
%
00
-
1.00
-
87